Stay updated with the most recent editions of ODT Magazine, featuring comprehensive coverage of the latest innovations and developments.
Access the full digital version of ODT Magazine, complete with interactive features and enhanced content for a seamless reading experience.
Join the ODT community! Subscribe to receive the latest industry news and insights delivered directly to your mailbox.
Discover how 3D printing and additive manufacturing are revolutionizing orthopedic device design and production processes.
Learn about contract manufacturing solutions in the orthopedic sector, emphasizing quality, compliance, and operational excellence.
Stay informed on the latest research and development trends in orthopedic device design, driving innovation and patient care improvements.
Explore the latest advancements in surgical instruments and technologies that enhance precision and outcomes in orthopedic procedures.
Discover cutting-edge machining and laser processing techniques that improve the quality and performance of orthopedic devices.
Learn about the innovative materials shaping orthopedic devices, focusing on performance, biocompatibility, and regulatory compliance.
Stay updated on advanced molding techniques for producing high-quality orthopedic components that meet industry standards.
Explore best practices for packaging and sterilization methods that ensure the safety and efficacy of orthopedic devices.
Discover the role of software solutions in enhancing orthopedic device design, functionality, patient management, and regulatory compliance.
Learn about essential testing methods and standards that ensure the safety, reliability, and effectiveness of orthopedic devices.
Stay ahead with real-time updates on significant news impacting the orthopedic device sector.
Access unique content and insights not available in the print edition of ODT Magazine, offering deeper dives into important topics.
Explore feature articles that provide in-depth analysis on specific topics within orthopedic design and technology.
Gain insights from industry experts through regular columns addressing critical challenges and innovations in orthopedics.
Read the editorial insights on current trends and highlights from the latest issue of ODT Magazine.
Discover leading companies in orthopedic design and technology, showcasing their innovations and contributions to the field.
Explore detailed profiles of companies in the orthopedic device manufacturing sector, highlighting their capabilities and offerings.
Learn about the expertise and resources of leading companies in the orthopedic device manufacturing sector.
Watch informative videos featuring industry leaders discussing trends, technologies, and innovations in orthopedic design.
Enjoy short, engaging videos that provide quick insights and updates on key topics within orthopedics.
Tune in to discussions with industry experts sharing their insights on trends, challenges, and innovations in orthopedic technology.
Participate in informative webinars led by industry experts covering various relevant topics in orthopedic design and manufacturing.
Stay informed on the latest press releases and announcements from leading companies in the orthopedic device manufacturing sector.
Access comprehensive eBooks that delve into various topics in orthopedic device manufacturing and innovation.
Highlighting the pioneers and innovators driving advancements in orthopedic technology and patient care.
Explore sponsored articles and insights from leading companies in the orthopedic industry.
Read in-depth whitepapers that examine key issues, trends, and research findings in orthopedic design and technology.
Discover major industry events, trade shows, and conferences focused on orthopedic technology and innovations.
Get real-time updates and insights from major industry shows and exhibitions happening around the world.
Participate in the ODT Forum, addressing orthopedic design and manufacturing technology trends, innovations, and industry challenges.
Attend the MPO Summit for insights and strategies from industry leaders shaping the future of medical device technology.
Join discussions and networking opportunities at the MPO Medtech Forum, focusing on the latest trends and challenges in the industry.
Explore advertising opportunities with ODT to connect with a targeted audience of orthopedic professionals.
Review our editorial guidelines for submissions and contributions to ODT.
Read about our commitment to protecting your privacy and personal information.
Familiarize yourself with the terms and conditions governing the use of odtmag.com.
What are you searching for?
Collaboration aims to take specially treated alloy from laboratory to surgical suite.
October 5, 2017
By: NYU Tandon School of Engineering
Titanium is the preferred material for surgical fixation procedures ranging from knee replacement to jaw implants. However, since this super-strong metal is not absorbed by the body over time, it can cause complications like infection, fistulization (particularly following radiation therapy), interference with skeletal growth, intolerance, thermal sensitivity, and interference with MRI and other imagining procedures. Additional procedures to remove hardware are among the most common surgeries worldwide and a major cost for hospitals. A promising alternative is magnesium, a safely biodegradable metal and cofactor for many enzymes in DNA repair that also promotes bone health. But while its physical properties make it suitable for load-bearing sites, such as the temporomandibular region of the jaw, its rapid breakdown in the body sometimes results in the formation of hydrogen bubbles that can lead to serious complications. In a unique collaboration, researchers at the NYU Tandon School of Engineering, NYU School of Medicine, and NYU Dentistry are developing and testing alloys of magnesium that are treated to improve strength and slow down the degradation process, thereby avoiding the formation of these bubbles. In research published in the Journal of Cranio-Maxillofacial Surgery, the team, which includes Nikhil Gupta, associate professor of mechanical and aerospace engineering at NYU Tandon; Paulo Coelho, the Dr. Leonard I. Linkow Professor at NYU Dentistry; Eduardo D. Rodriguez, Helen L. Kimmel Professor of Reconstructive Plastic Surgery and chair, Hansjörg Wyss Department of Plastic Surgery at NYU School of Medicine; and Andrea Torroni, MD, associate professor, Wyss Department of Plastic Surgery at NYU School of Medicine, reported on their tests of a magnesium alloy that was subjected in Gupta’s lab to a process called T-5 tempering, involving heating at 210 degrees Celsius for 48 hours. After surgically implanting small samples of the alloy in the fronto-nasal region of study animals, the team examined the accumulation of the element in the lymph nodes, finding no difference between animals with no implants and the study animals. The researchers also implanted untreated—or “as-cast”—alloy, finding that both the as-cast samples and T-5 heat-treated alloys showed good biocompatibility and promoted bone growth in test animals. The T-5 alloy, however, was much more stable, with an eight-fold lower degradation rate than the as-cast alloy. Gupta said he was not surprised by the positive results, as they mirrored what he had observed during in vitro studies at NYU Tandon. “In our lab we put both as-cast and the heat-treated alloy in a solution of sodium chloride to simulate body fluid environments. Not surprisingly, the as-cast version corroded a lot. However, the heat-treated version did not corrode at all,” he said. “What we have discovered is that by employing heat treatment we can change the alloy completely from a degradable, resorbable structure to one that doesn’t degrade over time. In essence, heat treatment makes magnesium behave, in vitro and in vivo, more like titanium.” Torroni thinks the results auger well for eventual clinical applications of T-5 magnesium, whose mechanical properties are comparable to titanium, even in mandibular fractures, where stress on bone is particularly high. “The T-5 is really the best candidate for these high-stress applications. It has superior properties that are very close to those of bone and is very good for fixation of fractures,” he explained. “It exhibits lower long-term risks because it resorbs. And it can promote bone formation and bone healing. It is totally biocompatible with no risk of rejection, and limited risk of infection.” The team also discerned no post-surgical morbidity, even in the control animals that received implants of untreated magnesium. “Because of magnesium’s systemic absorbability, this is not a problem,” said Coelho. “The key idea is to make an implant that can be either non-absorbable, as a permanent support, or absorbable, like sutures that go away after some time.” Gupta said that the research would not have been possible without collaboration between NYU institutions. “The breadth of this research takes it from the lab all the way to a clinical setting,” he added. Find more information on the study here.
Enter your account email.
A verification code was sent to your email, Enter the 6-digit code sent to your mail.
Didn't get the code? Check your spam folder or resend code
Set a new password for signing in and accessing your data.
Your Password has been Updated !